5361 Highway
54
Owensboro, KY 42303
(866) 605-4328 toll free
(270) 852-8733 office
(270) 852-8734 fax
Email Us
|
|

Waste Oil Boiler
- Model B500
with the reliable KAGI burner
| Model |
B500 |
| BTU Input |
500,000 BTU |
| Square Foot
Coverage |
17,500 square
feet |
| Fuel Flow Rate |
3.6 gal/hr |
| ASME Code Vessel |
Built to
"H-2" Specs |
| Max Water Output
Temperature |
230 degrees F |
| Max Operating
Pressure |
|
| Optional
Domestic Hot Water Output |
8.0 or 16.0 gal/min |
| Boiler Capacity |
58 gallon
system |
| Dimensions |
45" H x 32" W
x 72" D |
| Exhaust Diameter |
10 " |
| Electric
Requirements |
115 VAC,
60Hz, 20 amps |
| Shipping Weight |
1030 lbs |
| Compressed Air
Requirements |
3CFM @ 40 PSI
minimum |
View other Waste Oil Boiler Systems
AgSolutions Waste
Oil Boiler Systems equipped with:
-
Kagi Burner
-
Re-Usable Oil Filter
with Indicator Gauge
-
Low Water Cut Off
-
Pressure Relief Valve
Combo
-
Pressure/Temperature
Gauge
-
High Limit Temperature
Controller
-
Operating Temperature
Controller
-
Barometric Damper
Waste Oil Boiler
Specifications:
Boiler Unit:
-
Wet base, horizontal
firetube, A.S.M.E. H-2
Code constructed.
-
30 psi boiler with
National Board
Registration Number.
-
Shell and combustion
chamber made of SA36
grade carbon steel , 1/4
inch thick.
-
Tube sheet made of SA36
grade carbon steel, 5/16
inch thick.
-
Tubes made of SA178A
grade 12 gauge carbon
steel.
-
Boiler has welded tubes
and no economizers in
the tubes.
-
two aquastat wells
installed.
-
burner
door hinged on the left
side complete with
ceramic fiber board
insulation, sight door
and handles.
-
Flue collector box
complete with removal
cover allowing straight
through access to boiler
tubes and to breeching.
-
Nuts for bolts for
access door and
collector box are brass
to reduce heat-related
binding.
-
Boiler block is black
-
4"
legs, bolted to skid for
shipment.
-
shipped with cover
jacket and insulation
blanket removed. The
boiler vessel itself is
in a single section.
Waste Oil Boiler Jacket:
-
20 gauge jacket with
1.1# density fiberglass
insulation.
-
Jacket cover color is
blue.
-
shipped with cover
jacket and insulation
blanket removed
Contact us for
current
pricing and shipping quotes.

Lease Options Available
Waste oil can not be burned in
all states.
Most states have adopted the
EPA requirements as guidelines.
Check with your state
and local agencies.
|
|